<LOGO>
FM Transmitter Measurement Report
Created: 2024-02-27 00-34-58
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
88.50 MHz 5/5, 42 dBuV R-ZURNAL
Pilot RDS Phase Difference
6.1 kHz 3.6 kHz 70 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
10 kHz 41 kHz 18913 0,3067
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,6 dBr -0,31 dBr 0,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-ZURNAL" 232F 3 (Info) 1 0 1 1 0:34, 27.02.2024
RT
"Zelena vlna - volejte be "
AF EON
89.7, 90.9, 91.3, 93.1, 94.6, 95.1, 95.9 MHz -
FM Scope Max at: 41 kHz MIN: 10 kHz % above 77 kHz: 0,3067 Acquired: 2024/02/27 0:34:55 Total samples: 18913 Equivalent time: 0:15:45 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 0,0 dBr MIN: -0,6 dBr AVE: -0,31 dBr % above 0,2 dBr: 0,0 Last value: -0,2 dBr (2024/02/27 0:34:55) 00:22 00:24 00:26 00:28 00:30 00:32 00:34 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality